How Fire Alarm Components Work Together
Process and Components of a Fire Alarm System
Input
Detector (smoke detector, heat detector, flame detector, gas detector). To test it, you can use a smoke detector tester.
Manual Call Point (break glass, pull station, push station).
Process
The Fire Alarm Control Panel (FACP) is the central control device of a fire alarm system. You could say the panel is the main control of the fire alarm. The control panel receives information from the detectors or Manual Call Points, processes it according to its programmed settings, and then activates the alarm (bell) or controls other devices integrated with the panel.
Output (Audio, Visual & Audio Visual)
Alarm Bell / Horn
Indicator / Strobe Light
Fire Alarm Systems by Working Principle
Conventional
Every input device connected to the control panel is grouped by zone/group. It works by connecting the detectors to the main control panel with a two-core cable. The system works in parallel, which means the installed detectors have a start point and an end point. The whole system from the start point to the end point is called a zone. Each zone usually consists of several detectors. When a detector picks up signs of a fire, the system sends a light signal for the zone where the fire is and gives a warning by sounding the alarm.
Addressable Fire Alarm
An addressable fire alarm system is one in which every device connected directly to the control panel (input or output) has its own identification (its own address) on its fire detector. This way, when a fire breaks out, the system immediately sends the alarm and the detector's light signal. The advantage of this system is that it makes it easy to locate the fire accurately, so the right evacuation route can be identified quickly and people have more time to evacuate.
Fire Alarm Control System Technology
Conventional system: a fire detection system that uses thermal or voltage changes, or directly detects changes in the state of the detectors in the field.
- Intelligent system: a fire detection system that processes thermal or voltage changes electronically, for example with a "thermal integrated circuit", which gives more accurate results, allows adjustments and shows the actual conditions.
- There are 2 kinds of intelligent system:
- Full Addressable: this system gives an "address" to every IDC, so detailed status can be obtained both for the area that uses the IDC and for the IDC itself. IDCs are commonly known as "addressable detectors".
- Semi Addressable: this system uses modules that are given addresses. Each module represents an area (zone) fitted with conventional detectors. The number of conventional detectors a module can handle is generally based on smoke detectors. That smoke detector capacity depends on the type of detector and the vendor that makes it.
Read also: Types of PABX Installation