The Difference Between Addressable and Conventional Fire Alarms

In a previous post, we covered what a fire alarm is and its types. If you haven't read it yet, please take a look.

In this article, we want to discuss the difference between addressable fire alarms and conventional fire alarms. Are these terms unfamiliar to you? Or do you already know them?

Read on to the end.

Differences Between Addressable and Conventional Fire Alarms

In terms of function, these two types of fire alarm system are actually not very different: both serve to warn of a fire. So what is the difference? Let's group the differences into the following 3 types.

1. Differences in Function

The first difference is in how they function. True, both serve as a warning when a fire breaks out. But if you look more closely at the system, that is where the differences lie.
An addressable fire alarm system sends a fire signal directly from the detector ID in the system, so we can know exactly where the fire is, while a conventional fire alarm system only sends a signal about the location of the fire, and this is looped to several detectors. For this reason, the conventional system is highly recommended for buildings that are not too large but still want a fairly high safety standard.

An addressable fire alarm system, on the other hand, is very complex to install, because it uses a great many modules for the needs of the system.

2. Differences in Cable Installation

The next difference is the cable installation of these fire alarm systems. A conventional fire alarm system uses NYM cable measuring 2 x 1.5 MM, or alternatively NYMHY cable measuring 2 x 1.5 MM.

In a conventional fire alarm system, the detectors are usually connected in parallel to special terminals, usually labeled L (positive/+) and Lc (negative/-). It is this cable that connects to the main panel. But this also depends on how many zones are used. Usually, one zone has several detectors.

If you have a 5-story building, you need to label each floor one by one; for example, floor 1 is labeled zone 1, floor 2 is labeled zone 2, and so on. Keep in mind that each floor may have a different number of detectors: zone 1 might have 6 detectors, while zone 2 has only 4.

An addressable fire alarm system, by contrast, is simpler: we don't use the L and C system, but a terminal called the loop terminal. Quite a large number of detectors can be connected to this loop terminal, up to an estimated 127 detectors. This is so that every detector ID is matched within 1 control panel, the main panel.

3. Differences in Price

The last difference is the price of each system. Although both serve the same function, the price difference comes from differences in the results and in the system used to perform that function.

An addressable fire alarm system is more expensive than a conventional fire alarm system, because the addressable system can report a fire more effectively and efficiently than a conventional fire alarm system.

Conclusion

Now that you know the differences between these types of fire alarm, you should be able to decide which fire alarm system to buy and install in your building.

If you are still unsure about fire alarms, Gelora Perkasa is the right place to come for advice. Contact our specialist team today. We hope this helps.


Gelora Perkasa Editorialauthor

Every article here is written and checked by the Gelora Perkasa team: the engineers and technicians who survey sites and install and maintain CCTV, fire alarm, PABX and network systems across Bali, Java and Lombok. We write about what we run into on real projects, so the advice comes from the field, not from a product brochure.